<https://sepses.org/resource/icsa/ICSA-25-352-05> <http://purl.org/dc/terms/identifier> "ICSA-25-352-05" ;
	<http://purl.org/dc/terms/issued> "2025-12-18T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2025-12-18T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens Interniche IP-Stack" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Critical Manufacturing" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2025-40820" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 7.5 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "High" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-940" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2025-40820> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-940> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Siemens Interniche IP-Stack" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "SIMATIC TDC CPU555; SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0); SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0); SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0); SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0); M12-L (6ES7142-6BR00-0BB0); SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0); SIPLUS S7-1200 CPU 1215C AC/DC/RLY (6AG1215-1BG40-2XB0); SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0); Modem Module ST (6ES7972-5AA51-0AB0); SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0); SIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-4XB0); SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0); SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0); SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0); SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0); SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0); SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0); SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0); M12-L (6ES7141-6BH00-0BB0); DQ 8x24VDC/2A; SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0); SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0); SIWAREX WP522 ST (7MH4980-2AA01); SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0); SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0); SIDOOR ATE530S COATED; Base Module (6ES7972-5AA10-0AB0); SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0); SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0); SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0); SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0); SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0); SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0); SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0); SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0); SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0); SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0); SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0); SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0); SIWAREX WP241 (7MH4960-4AA01); CM 8x IO-Link (6ES7148-7JH00-0BB0); SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0); SIMATIC ET 200eco PN; SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0); SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1); SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1); SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0); SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0); DI 16x24VDC; AI 8xRTD/TC; SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0); M12-L (6ES7144-6JF00-0BB0); M12-L (6ES7148-6JJ00-0BB0); SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0); SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0); M12-L (6ES7141-6BG00-0BB0); SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0); 5A (6ES7143-7BH00-0BB0); SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0); SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0); SIDOOR ATE530G COATED (6FB1221-5SM10-7BP0); DQ 8x24VDC/0; SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0); SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0); SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0); DIQ 16x24VDC/2A; SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0); SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0); CM 8x IO-Link; SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0); SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0); SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0); SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0); SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0); SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0); SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0); SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants); SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0); SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0); SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0); SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0); SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0); SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0); SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1); SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0); SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0); SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0); SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0); SIMATIC CFU PA (6ES7655-5PX11-1XX0); DI 16x24VDC (6ES7141-7BH00-0BB0); SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0); SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0); SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0); SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1); SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0); SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0); SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0); SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0); 5A; SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0); SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0); SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0); M12-L (6ES7142-6BG00-0BB0); SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0); M12-L (6ES7148-6JE00-0BB0); SINUMERIK 840D sl; SIMATIC Power Line Booster PLB; SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0); SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0); SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0); SIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-4XB0); SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0); SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0); SIMATIC CFU PA (6ES7655-5PX11-0XX0); SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0); SIMATIC ET 200clean; SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0); SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0); SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0); SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1); SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0); SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0); SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0); SIWAREX WP251 (7MH4960-6AA01); SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0); SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0); SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0); DIQ 16x24VDC/0; SIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0); SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0); SIMOCODE pro V PROFINET; CM 4x IO-Link; SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants); SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1); SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0); SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0); SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0); SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0); SIPLUS S7-1200 CPU 1212C AC/DC/RLY (6AG1212-1BE40-2XB0); SIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-4XB0); SIDOOR ATD430W; M12-L (6ES7148-6JG00-0BB0); SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0); SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0); SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1); SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0); SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0); SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0); SIWAREX WP521 ST (7MH4980-1AA01); SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants); SIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-5XB0); SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0); SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0); SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0); SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants); SIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-2XB0); SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0); SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0); SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0); M12-L (6ES7143-6BH00-0BB0); SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0); SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0); SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0); SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1); SIWAREX WP231 (7MH4960-2AA01); SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0); SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0); SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0); SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0); SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0); SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1); SIMATIC TDC CP51M1; SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0); SIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-5XB0); SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0); DI 8x24VDC; SIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-2XB0); SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0); SIMATIC CFU DIQ (6ES7655-5PX31-1XX0); SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0); SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0); SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants); SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-25-352-05" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2025 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .