<https://sepses.org/resource/icsa/ICSA-25-184-04> <http://purl.org/dc/terms/identifier> "ICSA-25-184-04" ;
	<http://purl.org/dc/terms/issued> "2025-07-03T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2025-07-03T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Mitsubishi Electric MELSEC iQ-F Series" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Japan" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Critical Manufacturing" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2025-5241" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 6.9 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Medium" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-645" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2025-5241> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-645> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "MELSEC iQ-F Series" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "FX5U-64MT/DSS: All versions; FX5U-80MT/ESS: All versions; FX5UJ-40MT/DSS: All versions; FX5UJ-24MT/DS: All versions; FX5UJ-24MT/ES-A: All versions; FX5UJ-60MT/DS: All versions; FX5U-64MR/DS: All versions; FX5U-80MT/DS: All versions; FX5UJ-60MR/ES-A: All versions; FX5S-30MR/DS: All versions; FX5S-40MT/DSS: All versions; FX5U-64MT/DS: All versions; FX5UJ-60MR/ES: All versions; FX5U-64MT/ES: All versions; FX5S-60MR/ES: All versions; FX5S-30MT/ES: All versions; FX5UJ-40MR/ES-A: All versions; FX5U-80MR/DS: All versions; FX5S-40MT/ES: All versions; FX5U-64MT/ESS: All versions; FX5-CCLGN-MS: All versions.; FX5UC-32MT/D: All versions; FX5UJ-40MR/ES: All versions; FX5UJ-60MT/ESS: All versions; FX5U-32MR/ES: All versions; FX5U-32MT/DSS: All versions; FX5UJ-24MR/ES-A: All versions; FX5S-60MT/DS: All versions; FX5S-60MR/DS: All versions; FX5UC-32MR/DS-TS: All versions; FX5S-30MT/DS: All versions; FX5UC-96MT/D: All versions; FX5S-60MT/ESS: All versions; FX5UJ-60MT/DSS: All versions; FX5S-40MR/ES: All versions; FX5UJ-24MR/ES: All versions; FX5U-32MR/DS: All versions; FX5S-60MT/DSS: All versions; FX5UC-64MT/DSS: All versions; FX5UJ-24MT/DSS: All versions; FX5S-60MT/ES: All versions; FX5S-80MR/ES: All versions; FX5S-30MT/DSS: All versions; FX5U-32MT/ESS: All versions; FX5U-64MR/ES: All versions; The following version of MELSEC iQ-F Series is affected: FX5U-32MT/ES: All versions; FX5U-80MR/ES: All versions; FX5UJ-60MR/DS: All versions; FX5S-80MT/ESS: All versions; FX5S-40MT/DS: All versions; FX5UJ-24MT/ESS: All versions; FX5UJ-40MT/ES: All versions; FX5UJ-40MR/DS: All versions; FX5S-30MR/ES: All versions; FX5UJ-40MT/DS: All versions; FX5UJ-60MT/ES: All versions; FX5S-80MT/ES: All versions; FX5UC-64MT/D: All versions; FX5UJ-40MT/ESS: All versions; FX5U-32MT/DS: All versions; FX5UC-96MT/DSS: All versions; FX5UJ-24MR/DS: All versions; FX5UJ-60MT/ES-A: All versions; FX5UJ-24MT/ES: All versions; FX5UC-32MT/DSS: All versions; FX5S-30MT/ESS: All versions; FX5S-40MR/DS: All versions; FX5U-80MT/DSS: All versions; FX5UC-32MT/DS-TS: All versions; FX5U-80MT/ES: All versions; FX5UC-32MT/DSS-TS: All versions; FX5UJ-40MT/ES-A: All versions; FX5S-40MT/ESS: All versions" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-25-184-04" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Mitsubishi Electric" ;
	<https://sepses.org/vocab/ref/icsa#year> 2025 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .