<https://sepses.org/resource/icsa/ICSA-25-135-05> <http://purl.org/dc/terms/identifier> "ICSA-25-135-05" ;
	<http://purl.org/dc/terms/issued> "2025-05-15T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2025-05-15T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens SIPROTEC and SICAM" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Critical Manufacturing" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2024-3596" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 9.1 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-924" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2024-3596> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-924> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "SIPROTEC and SICAM" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "Siemens reports the following products using the RADIUS protocol are affected: CPC80 Central Processing/Communication: All versions CPCI85 Central Processing/Communication: All versions POWER METER SICAM Q100 family: All versions prior to V2.70 POWER METER SICAM Q200 family: All versions Powerlink IP: All versions SICAM GridPass: All versions prior to V2.50 SICORE Base system: All versions SIPROTEC 5 Compact 7SX800 (CP050): All versions SIPROTEC 5 7SA82 (CP100): Versions V7.80 and after SIPROTEC 5 7SD82 (CP100): Versions V7.80 and after SIPROTEC 5 7SJ81 (CP100): Versions V7.80 and after SIPROTEC 5 7SJ82 (CP100): Versions V7.80 and after SIPROTEC 5 7SK82 (CP100): Versions V7.80 and after SIPROTEC 5 7SL82 (CP100): Versions V7.80 and after SIPROTEC 5 7UT82 (CP100): Versions V7.80 and after SIPROTEC 5 7SA82 (CP150): All versions SIPROTEC 5 7SD82 (CP150): All versions SIPROTEC 5 7SJ81 (CP150): All versions SIPROTEC 5 7SJ82 (CP150): All versions SIPROTEC 5 7SK82 (CP150): All versions SIPROTEC 5 7SL82 (CP150): All versions SIPROTEC 5 7SX82 (CP150): All versions SIPROTEC 5 7SY82 (CP150): All versions SIPROTEC 5 7UT82 (CP150): All versions SIPROTEC 5 6MD84 (CP300): All versions SIPROTEC 5 6MD85 (CP300): Versions V7.80 and after SIPROTEC 5 6MD86 (CP300): Versions V7.80 and after SIPROTEC 5 6MD89 (CP300): Versions V7.80 and after SIPROTEC 5 6MD89 (CP300) V9.6: Versions prior to V9.68 SIPROTEC 5 6MU85 (CP300): All versions SIPROTEC 5 7KE85 (CP300): Versions V7.80 and after SIPROTEC 5 7SA86 (CP300): Versions V7.80 and after SIPROTEC 5 7SA87 (CP300): Versions V7.80 and after SIPROTEC 5 7SD86 (CP300): Versions V7.80 and after SIPROTEC 5 7SD87 (CP300): Versions V7.80 and after SIPROTEC 5 7SJ85 (CP300): Versions V7.80 and after SIPROTEC 5 7SJ86 (CP300): Versions V7.80 and after SIPROTEC 5 7SK85 (CP300): Versions V7.80 and after SIPROTEC 5 7SL86 (CP300): Versions V7.80 and after SIPROTEC 5 7SL87 (CP300): Versions V7.80 and after SIPROTEC 5 7SS85 (CP300): Versions V7.80 and after SIPROTEC 5 7ST85 (CP300): Versions prior to V9.68 SIPROTEC 5 7ST86 (CP300): Versions prior to V9.83 SIPROTEC 5 7SX85 (CP300): All versions SIPROTEC 5 7UM85 (CP300): Versions V7.80 and after SIPROTEC 5 7UT85 (CP300): Versions V7.80 and after SIPROTEC 5 7UT86 (CP300): Versions V7.80 and after SIPROTEC 5 7UT87 (CP300): Versions V7.80 and after SIPROTEC 5 7VE85 (CP300): Versions V7.80 and after SIPROTEC 5 7VK87 (CP300): Versions V7.80 and after SIPROTEC 5 7VU85 (CP300): All versions." ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-25-135-05" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2025 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .