<https://sepses.org/resource/icsa/ICSA-24-051-03> <http://purl.org/dc/terms/identifier> "ICSA-24-051-03" ;
	<http://purl.org/dc/terms/issued> "2024-02-20T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2024-04-23T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Mitsubishi Electric Electrical Discharge Machines (Update A)" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Japan" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Critical Manufacturing" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2023-21554" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 9.3 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-20" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2023-21554> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-20> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Electrical discharge machines" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV4800R D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Sinker EDM SV-P Series SV8P D-CUBES Series Special system BRD-M63W000 to W022: all versions Sinker EDM SV-P Series SV12P D-CUBES Series Special system BRD-M63W000 to W022: all versions Sinker EDM SG Series SG8 D-CUBES Series Standard system BRD-M60W000: versions A12 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV2400R D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MP Series MP1200 D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MP Series MP2400 D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MP Series MP4800 D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MX Series MX900 D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV2400S D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MP Series MP2400 D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; Mitsubishi Electric reports that the following electrical discharge machines are affected by this vulnerability in Microsoft Message Queuing service: Wire-cut EDM MV Series MV1200S D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV1200R D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MP Series MP4800 D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Sinker EDM SV-P Series SV12P D-CUBES Series Standard system BRD-M60W000: versions A12 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MX Series MX900 D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MX Series MX2400 D-CUBES Series Special system BRD-B63W000 to W036: all versions Sinker EDM SV-P Series SV8P D-CUBES Series Standard system BRD-M60W000: versions A12 and prior; without Special Modification Patch BRD-C62W003-A0 installed Sinker EDM SG Series SG12 D-CUBES Series Standard system BRD-M60W000: versions A12 and prior; without Special Modification Patch BRD-C62W003-A0 installed Sinker EDM SG Series SG28 D-CUBES Series Standard system BRD-M60W000: versions A12 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV4800S D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MV Series MV1200S D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MV Series MV2400S D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MV Series MV4800S D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MV Series MV1200R D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MV Series MV2400R D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MV Series MV4800R D-CUBES Series Special system BRD-B63W000 to W036: all versions Wire-cut EDM MP Series MP1200 D-CUBES Series Standard system BRD-B60W000: versions B13 and prior; without Special Modification Patch BRD-C62W003-A0 installed Sinker EDM SG Series SG8 D-CUBES Series Special system BRD-BRD-M63W000 to W022: all versions Sinker EDM SG Series SG12 D-CUBES Series Special system BRD-M63W000 to W022: all versions Sinker EDM SG Series SG28 D-CUBES Series Special system BRD-M63W000 to W022: all versions.; without Special Modification Patch BRD-C62W003-A0 installed Wire-cut EDM MX Series MX2400 D-CUBES Series Standard system BRD-B60W000: versions B13 and prior" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-24-051-03" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Mitsubishi Electric" ;
	<https://sepses.org/vocab/ref/icsa#year> 2024 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .