<https://sepses.org/resource/icsa/ICSA-23-080-04> <http://purl.org/dc/terms/identifier> "ICSA-23-080-04" ;
	<http://purl.org/dc/terms/issued> "2023-03-21T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2023-03-21T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens RADIUS Client of SIPROTEC 5 Devices" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Energy" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2022-38767" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 7.5 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "High" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-835" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2022-38767> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-835> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "RADIUS client of SIPROTEC 5 devices" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "The following software from Siemens is affected: SIPROTEC 5 6MD85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 6MD86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 6MD89 (CP300) - >= V7.80 SIPROTEC 5 6MU85 (CP300) - >= V7.90 < V9.30 SIPROTEC 5 7KE85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SA86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SA87 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SD86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SD87 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SJ85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SJ86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SK85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SL86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SL87 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7SS85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7ST85 (CP300) - >= V8.81 < V9.30 SIPROTEC 5 7ST86 (CP300) - >= V9.20 < V9.30 SIPROTEC 5 7SX85 (CP300) - >= V8.30 < V9.30 SIPROTEC 5 7UM85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7UT85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7UT86 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7UT87 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7VE85 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 7VK87 (CP300) - >= V7.80 < V9.30 SIPROTEC 5 Communication Module ETH-BA-2EL - >= V7.80 < V9.30 SIPROTEC 5 Communication Module ETH-BB-2FO - >= V7.80 < V9.30 SIPROTEC 5 Communication Module ETH-BD-2FO - >= V7.80 < V9.30 SIPROTEC 5 Compact 7SX800 (CP050) - >= V8.70 < V9.30." ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-23-080-04" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2023 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .