<https://sepses.org/resource/icsa/ICSA-22-314-09> <http://purl.org/dc/terms/identifier> "ICSA-22-314-09" ;
	<http://purl.org/dc/terms/issued> "2022-11-10T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2022-12-15T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens Teamcenter Visualization and JT2Go (Update A)" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Critical Manufacturing" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2022-41664; CVE-2022-41661; CVE-2022-41663; CVE-2022-41660; CVE-2022-39136; CVE-2022-41662" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 7.8 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "High" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-125; CWE-416; CWE-121; CWE-787; CWE-122" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2022-39136>, <https://sepses.org/resource/cve/CVE-2022-41660>, <https://sepses.org/resource/cve/CVE-2022-41661>, <https://sepses.org/resource/cve/CVE-2022-41662>, <https://sepses.org/resource/cve/CVE-2022-41663>, <https://sepses.org/resource/cve/CVE-2022-41664> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-121>, <https://sepses.org/resource/cwe/CWE-122>, <https://sepses.org/resource/cwe/CWE-125>, <https://sepses.org/resource/cwe/CWE-416>, <https://sepses.org/resource/cwe/CWE-787> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Teamcenter Visualization and JT2Go" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "prior to V13.3.0.8 (only affected by CVE-2022-39136) --------- End Update A Part 1 of 2 --------- Teamcenter Visualization V13.3: All versions prior to V13.3.0.7 Teamcenter Visualization V14.0: All versions prior to V14.0.0.3 Teamcenter Visualization V14.1: All versions prior to V14.1.0.4.; The following software from Siemens is affected: JT2Go: All versions prior to V14.1.0.4 --------- Begin Update A Part 1 of 2 --------- Teamcenter Visualization V13.3: All versions V13.3.0.7 and later" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-22-314-09" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2022 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .