<https://sepses.org/resource/icsa/ICSA-21-131-11> <http://purl.org/dc/terms/identifier> "ICSA-21-131-11" ;
	<http://purl.org/dc/terms/issued> "2021-05-11T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2021-05-11T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens SIMATIC UltraVNC HMI WinCC Products" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Multiple Critical Sectors" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2019-8275; CVE-2019-8265; CVE-2019-8260; CVE-2019-8277; CVE-2019-8261; CVE-2019-8259; CVE-2019-8263; CVE-2019-8280; CVE-2019-8262; CVE-2019-8264" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 9.8 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-125; CWE-121; CWE-665; CWE-170; CWE-788; CWE-122" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2019-8259>, <https://sepses.org/resource/cve/CVE-2019-8260>, <https://sepses.org/resource/cve/CVE-2019-8261>, <https://sepses.org/resource/cve/CVE-2019-8262>, <https://sepses.org/resource/cve/CVE-2019-8263>, <https://sepses.org/resource/cve/CVE-2019-8264>, <https://sepses.org/resource/cve/CVE-2019-8265>, <https://sepses.org/resource/cve/CVE-2019-8275>, <https://sepses.org/resource/cve/CVE-2019-8277>, <https://sepses.org/resource/cve/CVE-2019-8280> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-121>, <https://sepses.org/resource/cwe/CWE-122>, <https://sepses.org/resource/cwe/CWE-125>, <https://sepses.org/resource/cwe/CWE-170>, <https://sepses.org/resource/cwe/CWE-665>, <https://sepses.org/resource/cwe/CWE-788> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "SIMATIC UltraVNC HMI WinCC Products" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "and KTP900F: All versions prior to v16 Update 4 SIMATIC WinCC Runtime Advanced: All versions prior to v16 Update 4.; KTP900; KTP700; The following Siemens SIMATIC HMIs/WinCC products are affected: SIMATIC HMI Comfort Outdoor Panels 7' and 15' (incl. SIPLUS variants): All versions prior to v16 Update 4 SIMATIC HMI Comfort Panels 4'to 22' (incl. SIPLUS variants): All versions prior to v16 Update 4 SIMATIC HMI KTP Mobile Panels KTP400F; KTP700F" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-21-131-11" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2021 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .