<https://sepses.org/resource/icsa/ICSA-20-154-04> <http://purl.org/dc/terms/identifier> "ICSA-20-154-04" ;
	<http://purl.org/dc/terms/issued> "2020-06-02T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2020-06-02T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "ABB Central Licensing System" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Switzerland" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Chemical; Critical Manufacturing; Dams; Energy; Food and Agriculture; Water and Wastewater" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2020-8481; CVE-2020-8471; CVE-2020-8475; CVE-2020-8479; CVE-2020-8476" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 9.8 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-200; CWE-611; CWE-264; CWE-400; CWE-284" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2020-8471>, <https://sepses.org/resource/cve/CVE-2020-8475>, <https://sepses.org/resource/cve/CVE-2020-8476>, <https://sepses.org/resource/cve/CVE-2020-8479>, <https://sepses.org/resource/cve/CVE-2020-8481> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-200>, <https://sepses.org/resource/cwe/CWE-264>, <https://sepses.org/resource/cwe/CWE-284>, <https://sepses.org/resource/cwe/CWE-400>, <https://sepses.org/resource/cwe/CWE-611> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Central Licensing System" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "The following ABB CLS products and versions are affected: ABB Ability System 800xA and related system extensions: Versions 5.1; 6.0; 6.1 Compact HMI: Versions 5.1; 6.0 Control Builder Safe: Versions 1.0; 1.1; 2.0 ABB Ability Symphony Plus - S+ Operations: Versions 3.0 to 3.2 ABB Ability Symphony Plus - S+ Engineering: Versions 1.1 to 2.2 Composer Harmony: Versions 5.1; 6.0; 6.1 Composer Melody (incl. SPE for Melody 1.0 SPx): Versions 5.3; 6.1; 6.2; 6.3 Harmony OPC Server (HAOPC): Standalone Versions 6.0; 6.1; 7.0 ABB Ability System 800xA / Advant OCS Control Builder A: Versions 1.3; 1.4 Advant OCS AC 100 OPC Server: Versions 5.1; 6.0; 6.1 Composer CTK: Versions 6.1; 6.2 AdvaBuild: Versions 3.7 SP1; 3.7 SP2 OPC Server MOD 300 (non-800xA): Version 1.4 OPC Data Link: Versions 2.1; 2.2 ABB Ability Knowledge Manager: Versions 8.0; 9.0; 9.1 ABB Ability Manufacturing Operations Management: Versions 1812; 1909." ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-20-154-04" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "ABB" ;
	<https://sepses.org/vocab/ref/icsa#year> 2020 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .