<https://sepses.org/resource/icsa/ICSA-20-042-02> <http://purl.org/dc/terms/identifier> "ICSA-20-042-02" ;
	<http://purl.org/dc/terms/issued> "2020-02-11T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2020-02-11T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens Industrial Products SNMP Vulnerabilities (Update D)" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Chemical; Energy; Food and Agriculture; Healthcare and Public Health; Transportation Systems; Water and Wastewater Systems" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2015-5621; CVE-2018-18065" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 7.5 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "High" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-476; CWE-19" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2015-5621>, <https://sepses.org/resource/cve/CVE-2018-18065> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-19>, <https://sepses.org/resource/cwe/CWE-476> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Various SCALANCE, SIMATIC, SIPLUS products" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "The following Siemens products are affected: IE/PB LINK PN IO (including SIPLUS NET variants): All versions prior to v4.0.1 SCALANCE S602: All versions prior to v4.1 SCALANCE S612: All versions prior to v4.1 SCALANCE S623: All versions prior to v4.1 SCALANCE S627-2M: All versions prior to v4.1; SIMATIC CP 1623: All versions prior to Version 14.00.15.00_51.25.00.01 SIMATIC CP 1626: All versions prior to v1.1.1 SIMATIC CP 1628: All versions prior to Version 14.00.15.00_51.25.00.01 SIMATIC CP 343-1 Advanced (including SIPLUS NET variants): All versions SIMATIC CP 443-1 (including SIPLUS NET variants): All versions SIMATIC CP 443-1 Advanced (including SIPLUS NET variants): All versions SIMATIC CP 443-1 OPC UA: All versions TIM 1531 IRC (including SIPLUS NET variants): All versions.; The following Siemens products are affected: IE/PB LINK PN IO (including SIPLUS NET variants): All versions prior to v4.0.1 SCALANCE S602: All versions prior to v4.1 SCALANCE S612: All versions prior to v4.1 SCALANCE S623: All versions prior to v4.1 SCALANCE S627-2M: All versions prior to v4.1; SIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0):All versions SIMATIC CP 443-1 (6GK7443-1EX30-0XE0): All versions SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0):: All versions SIMATIC CP 443-1 OPC UA (6GK7443-1UX00-0XE0): All versions SIMATIC CP 1623 (6GK1162-3AA00): All versions prior to v14.00.15.00_51.25.00.01 SIMATIC CP 1626 (6GK1162-6AA01): All versions prior to v1.1.1 SIMATIC CP 1628(6GK1162-8AA00): All versions prior to v14.00.15.00_51.25.00.01 SIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0): All versions SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0): All versions SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0): All versions; TIM 1531 IRC (including SIPLUS NET variants): All versions." ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-20-042-02" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2020 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .