<https://sepses.org/resource/icsa/ICSA-19-043-03> <http://purl.org/dc/terms/identifier> "ICSA-19-043-03" ;
	<http://purl.org/dc/terms/issued> "2019-02-12T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2019-05-14T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "WIBU SYSTEMS AG WibuKey Digital Rights Management (Update D)" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Commercial Facilities; Communications; Critical Manufacturing; Energy; Financial Services; Healthcare and Public Health; Transportation Systems" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2018-3989; CVE-2018-3991; CVE-2018-3990" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> "10.0"^^<http://www.w3.org/2001/XMLSchema#decimal> ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-200; CWE-122; CWE-787" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2018-3989>, <https://sepses.org/resource/cve/CVE-2018-3990>, <https://sepses.org/resource/cve/CVE-2018-3991> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-122>, <https://sepses.org/resource/cwe/CWE-200>, <https://sepses.org/resource/cwe/CWE-787> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "WIBU SYSTEMS AG WibuKey Digital Rights Management" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "Siemens products affected: WibuKey Digital Rights Management (DRM): Siemens SICAM 230: All Versions 7.20 and prior; Siemens SIMATIC WinCC OA:3.14: All versions prior to vP0253.15: All versions prior to vP0183.16: All versions prior to vP007. Siemens SISHIP EMCS; IPMS: All versions. | COPA-DATA zenon products: All Versions 7.20 and prior (7.50 and 7.60 may also be affected if WibuKey was installed manually) COPA-DATA straton workbench: All Versions 9.2 and prior | Sprecher Automation SPRECON-V460 products: All Versions 7.20 and prior (7.50 and 7.60 may also be affected if WibuKey was installed manually) | Phoenix Contact MEVIEW3: All versions prior to 3.14.25 and 3.15.18.; IMAC" ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-19-043-03" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Wibu-Systems AG" ;
	<https://sepses.org/vocab/ref/icsa#year> 2019 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .