<https://sepses.org/resource/icsa/ICSA-18-093-01> <http://purl.org/dc/terms/identifier> "ICSA-18-093-01" ;
	<http://purl.org/dc/terms/issued> "2018-04-03T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/modified> "2018-04-05T00:00:00"^^<http://www.w3.org/2001/XMLSchema#dateTime> ;
	<http://purl.org/dc/terms/title> "Siemens Building Technologies Products (Update A)" ;
	<https://sepses.org/vocab/ref/icsa#companyHeadquarter> "Germany" ;
	<https://sepses.org/vocab/ref/icsa#criticalInfrastructureSector> "Commercial Facilities" ;
	<https://sepses.org/vocab/ref/icsa#cveNumber> "CVE-2017-12822; CVE-2017-11498; CVE-2017-12820; CVE-2017-12818; CVE-2017-11497; CVE-2017-11496; CVE-2017-12821; CVE-2017-12819" ;
	<https://sepses.org/vocab/ref/icsa#CVSSScore> 9.8 ;
	<https://sepses.org/vocab/ref/icsa#CVSSSeverity> "Critical" ;
	<https://sepses.org/vocab/ref/icsa#cweNumber> "CWE-476; CWE-121; CWE-776; CWE-119; CWE-284; CWE-122; CWE-254" ;
	<https://sepses.org/vocab/ref/icsa#hasCVE> <https://sepses.org/resource/cve/CVE-2017-11496>, <https://sepses.org/resource/cve/CVE-2017-11497>, <https://sepses.org/resource/cve/CVE-2017-11498>, <https://sepses.org/resource/cve/CVE-2017-12818>, <https://sepses.org/resource/cve/CVE-2017-12819>, <https://sepses.org/resource/cve/CVE-2017-12820>, <https://sepses.org/resource/cve/CVE-2017-12821>, <https://sepses.org/resource/cve/CVE-2017-12822> ;
	<https://sepses.org/vocab/ref/icsa#hasCWE> <https://sepses.org/resource/cwe/CWE-119>, <https://sepses.org/resource/cwe/CWE-121>, <https://sepses.org/resource/cwe/CWE-122>, <https://sepses.org/resource/cwe/CWE-254>, <https://sepses.org/resource/cwe/CWE-284>, <https://sepses.org/resource/cwe/CWE-476>, <https://sepses.org/resource/cwe/CWE-776> ;
	<https://sepses.org/vocab/ref/icsa#license> "Open Database License (ODbL) v1.0 - 2026 ICS Advisory Project" ;
	<https://sepses.org/vocab/ref/icsa#product> "Building Technologies Products" ;
	<https://sepses.org/vocab/ref/icsa#productDistribution> "Worldwide" ;
	<https://sepses.org/vocab/ref/icsa#productsAffected> "Siemens License Management System (LMS) which includes a vulnerable version of Gemalto Sentinel LDK RTE is used by the following Siemens products and solutions: License Management System (LMS) All versions prior to V2.1 SP3(2.1.670) | Annual Shading V1.0.4 and 1.1 | Desigo ABT Versions | MP1.1 Build 845 | MP1.15 Build 360 | MP1.16 Build 055 | MP1.2 Build 850 | MP1.2.1 Build 318 | MP2.1 Build 965 | Desigo CC Versions | MP1.1 | MP2.0 | MP2.1 | MP3.0 | Desigo Configuration Manager (DCM) V6.10.140 | Desigo XWP | V5.00.204 | V5.00.260 | V5.10.142 | V5.10.212 | V6.00.184 | V6.00.342 | V6.10.172 | SiteIQ Analytics | V1.1 | V1.2 | V1.3 | Siveillance Identity V1.1." ;
	<https://sepses.org/vocab/ref/icsa#reference> "https://www.cisa.gov/news-events/ics-advisories/ICSA-18-093-01" ;
	<https://sepses.org/vocab/ref/icsa#vendor> "Siemens" ;
	<https://sepses.org/vocab/ref/icsa#year> 2018 ;
	a <https://sepses.org/vocab/ref/icsa#ICSA> .